B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 343 -
4.42 PARAMETERS OF MANUAL HANDLE FEED, HANDLE
INTERRUPTION AND HANDLE FEED IN TOOL AXIAL
DIRECTION
#7 #6 #5 #4 #3 #2 #1 #0
7100 HCL THD JHD
[Input type] Parameter input
[Data type] Bit path
# 0 JHD Manual handle feed in JOG feed mode or incremental feed in the
manual handle feed
0: Invalid
1: Valid
# 1 THD In the TEACH IN JOG mode, the manual pulse generator is:
0: Disabled.
1: Enabled.
# 3 HCL The clearing of handle interruption amount display by soft key [CAN]
operation is:
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
7102 HNGx
[Input type] Parameter input
[Data type] Bit axis
# 0 HNGx Axis movement direction for rotation direction of manual pulse
generator
0: Same in direction
1: Reverse in direction
#7 #6 #5 #4 #3 #2 #1 #0
7103 HIT HNT RTH
[Input type] Parameter input
[Data type] Bit path
# 1 RTH By a reset or emergency stop, the amount of manual handle
interruption is:
0: Not canceled.
1: Canceled.
# 2 HNT When compared with the travel distance magnification selected by the
manual handle feed travel distance selection signals (incremental feed
signals) (MP1, MP2), the travel distance magnification for
incremental feed/manual handle feed is: