B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 425 -
8492 Minimum tolerance for a block where smooth interpolation is applied
[Input type] Setting input
[Data type] Real path
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets a tolerance for deciding whether to perform
smooth interpolation. For a block that has a tolerance less than the
value set in this parameter, smooth interpolation is not performed.
Usually, set a value of about 1/10 of the maximum tolerance value (set
in parameter No. 8491). When 0.0 is set, 1/10 of the maximum
tolerance (set in parameter No. 8491) is used as a minimum tolerance.
When a negative value is set, a minimum tolerance of 0.0 is assumed.