B-63950EN/02 3.INPUTTING AND OUTPUTTING PARAMETERS THROUGH THE READER/PUNCHER INTERFACE
- 17 -
3.3.15 Real Number Path Format
N ***** Q1 L ** P ****** L ** P ******
・ ・ ・
;
N ***** Q1 L ** M ****** L ** M ******
・ ・ ・
;
N ***** Q1 L ** I ****** L ** I ******
・ ・ ・
;
A numeric value after N represents a parameter number.
Q1 indicates that the data is parameter data.
A numeric value after L represents a path number (1 and up).
A numeric value after each of P, M, and I represents the value (real
number) of a parameter for each path.
A semicolon (;) marks the end of a block. (LF is used for the ISO
code, and CR is used for the EIA code.)
Example
N01220Q1L1M50.0L2M60.0L3M70.0 ;
Parameter No. 1220
Parameter value Path 1: 50.0
Path 2: 60.0
Path 3: 70.0