B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 459 -
4.66 PARAMETERS OF MALFUNCTION PROTECTION
12255 Maximum servo motor speed
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
This parameter sets a maximum servo motor speed. When the value
set in this parameter is exceeded, the servo motor stops with the alarm
(DS0004). When 0 is set in this parameter, the specification of a
maximum allowable value (999000 for IS-B) is assumed.
12256 Maximum servo motor acceleration rate
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/sec/sec, inch/sec/sec, degree/sec/sec (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (D)
(When the machine system is metric system, 0.0 to +100000.0. When
the machine system is inch system, machine, 0.0 to +10000.0)
This parameter sets a maximum servo motor acceleration rate. When
the value set in this parameter is exceeded, the servo motor stops with
the alarm (DS0005). When 0 is set in this parameter, alarm check is
not performed.