4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 340 -
4.41 PARAMETERS OF MANUAL OPERATION AND
AUTOMATIC OPERATION
#7 #6 #5 #4 #3 #2 #1 #0
7001 JSN JST ABS
[Input type] Parameter input
[Data type] Bit path
# 1 ABS For the move command after manual intervention in the manual
absolute on state:
0: Different paths are used in the absolute (G90) and incremental
(G91) modes.
1: The same path (path in the absolute mode) is used in the absolute
(G90) and incremental (G91) modes.
# 2 JST In manual numerical specification, the STL signal indicating that
automatic operation is being started is:
0: Not output.
1: Output.
# 4 JSN When an S code is specified with the manual numerical specification
function, the modal display of the S code is:
0: Not updated.
1: Updated.
#7 #6 #5 #4 #3 #2 #1 #0
7002 JBF JTF JSF JMF
[Input type] Parameter input
[Data type] Bit path
# 0 JMF In manual numerical specification, M function specification is:
0: Allowed.
1: Not allowed.
# 1 JSF In manual numerical specification, S function specification is:
0: Allowed.
1: Not allowed.
# 2 JTF In manual numerical specification, T function specification is:
0: Allowed.
1: Not allowed.
# 3 JBF In manual numerical specification, B function specification is:
0: Allowed.
1: Not allowed.