B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 443 -
10316 Lower limit of a workpiece zero point offset range No.01
to to
10321 Lower limit of a workpiece zero point offset range No.06
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to maximum number of offset sets
Each of these parameters sets the lower limit of a workpiece zero point
offset range. For an additional workpiece coordinate system, set a
value after adding 1000.
These parameters correspond to the workpiece zero point offset
lower/upper limits set in parameter Nos. 10304 to 10315.
10322 Upper limit of a workpiece zero point offset range No.01
to to
10327 Upper limit of a workpiece zero point offset range No.06
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to maximum number of offset sets
Each of these parameters sets the upper limit of a workpiece zero
point offset range. For an additional workpiece coordinate system, set
a value after adding 1000.
These parameters correspond to the workpiece zero point offset
lower/upper limits set in parameter Nos. 10304 to 10315.
10328 Lower limit of workpiece shifts
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets a workpiece shift lower limit.
10329 Upper limit of workpiece shifts
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)