4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 458 -
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Each of these parameters sets the maximum value of the operation
range of each of the eleventh to sixteenth high-speed position switches.
If such a setting that maximum value < minimum value is made, no
operation range exists, so that the high-speed position switch does not
operate.
12241
Minimum value of the operation range of the eleventh high-speed position
switch
12242
Minimum value of the operation range of the twelfth high-speed position
switch
12243
Minimum value of the operation range of the thirteenth high-speed position
switch
12244
Minimum value of the operation range of the fourteenth high-speed position
switch
12245
Minimum value of the operation range of the fifteenth high-speed position
switch
12246
Minimum value of the operation range of the sixteenth high-speed position
switch
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Each of these parameters sets the minimum value of the operation
range of each of the eleventh to sixteenth high-speed position switches.
If such a setting that maximum value < minimum value is made, no
operation range exists, so that the high-speed position switch does not
operate.