B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 213 -
4811
Allowable error count for the error pulses between two spindles in the
spindle synchronization control mode
[Input type] Parameter input
[Data type] Word spindle
[Unit of data] Detection unit
[Valid data range] 0 to 32767
Set the allowable error count for the error pulses between two spindles
in the spindle synchronization control mode.
This parameter is used to check a spindle synchronization error phase
difference.
When a spindle synchronization error equal to or greater than the
value set in this parameter is detected, the phase error monitor signals
SYCAL<F044.4> and SYCAL1 to 4<F043.0 to 3> are set to 1.
4821 Master axis of each slave spindle under simple synchronous spindle control
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte spindle
[Valid data range] 0 to Maximum number of controlled axes (within a path)
When a spindle is set as a slave spindle in simple spindle synchronous
control on each spindle, set which spindle (master spindle) the slave
spindle is to be synchronized with.
Examples of parameter setting)
- When simple spindle synchronous control is exercised with the
first spindle selected as a master spindle and the second spindle
selected as a slave spindle
No.4821(1)=1
No.4821(2)=1
No.4821(3)=0
No.4821(4)=0
- When simple spindle synchronous control is exercised with four
spindles under the following combinations:
(Two combinations, namely, first spindle (master spindle)/
second spindle (slave spindle), and third spindle (master
spindle)/fourth spindle (slave spindle))
No.4821(1)=0
No.4821(2)=1
No.4821(3)=0
No.4821(4)=3