4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 344 -
0: Same.
1: 10 times greater.
# 3 HIT When compared with the travel distance magnification selected by the
manual handle feed travel distance selection signals (incremental feed
signals (MP1, MP2), the travel distance magnification for manual
handle interrupt is:
0: Same.
1: 10 times greater.
#7 #6 #5 #4 #3 #2 #1 #0
7105 LBH HDX
[Input type] Parameter input
[Data type] Bit
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 1 HDX Manual handle for I/O Link connection is:
0: Automatically set.
1: Manually set.
NOTE
For the setting, use parameters Nos. 12300 to
12302.
# 5 LBH Manual handle feed for the I/O Link β using the I/O link manual pulse
generator is:
0: Disabled.
1: Enabled.
7113 Manual handle feed magnification m
[Input type] Parameter input
[Data type] Word path
[Valid data range] 1 to 2000
This parameter sets the magnification m when manual handle feed
movement selection signals MP1 and MP2 are set to 0 and 1.