B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 185 -
#7 #6 #5 #4 #3 #2 #1 #0
3704 CSS SSY SSS
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 4 SSS Synchronous spindle control by each spindle is:
0: Not performed.
1: Performed.
The master axis and slave axis of synchronous spindle control can be
selected from the arbitrary spindles.
The target spindle of synchronous spindle control is specified in
parameter No. 4831.
In addition, the following signals affect the control.
In addition, the following signals affect the control.
- Synchronous spindle signals of each spindle SPSYCs
- Signals of synchronous control of the spindle phase for each
spindle SPPHSs
# 5 SSY Simple synchronous spindle control by each spindle is:
0: Not performed.
1: Performed.
The master axis and slave axis of simple synchronous spindle control
can be selected from the arbitrary spindles.
The target spindle of simple synchronous spindle control is set in
parameter No. 4821.
In addition, the following signals affect the control.
- Signals of simple synchronous control of each spindle ESSYCs
- Parking signals of simple synchronous control of each spindle
PKESEs
# 7 CSS On the each spindle, Cs contour control is:
0: Not performed.
1: Performed.