4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 166 -
Parameter G code group
C01 01
C02 02
C03 03
: :
D30 30
# 7 CFH When parameter CLR (No.3402#6) is 1, the reset button on the MDI
panel, the external reset signal, the reset and rewind signal, or
emergency stop will,
0: Clear F codes, H codes (for the M series), D codes (for the M
series), and T codes (for the T series).
1: Not clear F codes, H codes (for the M series), D codes (for the M
series), and T codes (for the T series).
3410 Tolerance of arc radius
[Input type] Setting input
[Data type] Real path
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 0 to 999999999
When a circular interpolation command is executed, the tolerance for
the radius between the start point and the end point is set.
3411 M code preventing buffering 1
3412 M code preventing buffering 2
:
3420 M code preventing buffering 10
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 0 to 999999999
Set M codes that prevent buffering the following blocks. If
processing directed by an M code must be performed by the machine
without buffering the following block, specify the M code.
M00, M01, M02, and M30 always prevent buffering even when they
are not specified in these parameters.