4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 486 -
#7 #6 #5 #4 #3 #2 #1 #0
13240 MT4 MT3 MT2 MT1
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Bit system common
# 0 MT1 The first cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13222 is invalid.
# 1 MT2 The second cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13227 is invalid.
# 2 MT3 The third cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13232 is invalid.
# 3 MT4 The fourth cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13237 is invalid.
13241 Number of rows of the first cartridge (when the cartridge is of the matrix
type)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 0 to 1000
When the first cartridge is of the matrix type (bit 0 (MT1) of
parameter No. 13240 is set to 1), set the number of rows in the pot in
this parameter. The setting must satisfy the following condition,
however: The sum total of the value obtained by (setting of
parameter No. 13241) × (setting of parameter No. 13242) and the
number of pots of other cartridges should not exceed 64 (1000 at
maximum). If this condition is not satisfied or this parameter is set to
0, the first cartridge is invalid.