4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 328 -
6282 Feedrate for the skip function (G31, G31 P1)
6283 Feedrate for the skip function (G31 P2)
6284 Feedrate for the skip function (G31 P3)
6285 Feedrate for the skip function (G31 P4)
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Each of these parameters sets a feedrate for each skip function G code.
These parameters are valid when bit 2 (SFN) of parameter No. 6207 is
set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
6286 TQO
[Input type] Parameter input
[Data type] Bit axis
# 0 TQO The torque limit override function is:
0: Disabled. (Override of 100%)
1: Enabled.
6287 Positional deviation limit in torque limit skip
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 327670
This parameter sets a positional deviation limit for each axis imposed
when torque limit skip is specified. When the actual positional
deviation exceeds the positional deviation limit, the alarm (SV0004) is
issued and an immediate stop takes place.