B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 33 -
4.5.3 Parameters of Channel 1 (I/O CHANNEL=1)
#7 #6 #5 #4 #3 #2 #1 #0
0111 NFD ASI SB2
[Input type] Parameter input
[Data type] Bit
# 0 SB2 The number of stop bits
0: 1
1: 2
# 3 ASI Code used at data input
0: EIA or ISO code (automatically distinguished)
1: ASCII code
# 7 NFD Feed before and after the data at data output
0: Output
1: Not output
0112
Number specified for the input/output device (when the I/O CHANNEL is set
to 1)
[Input type] Parameter input
[Data type] Byte
[Valid data range] 0 to 6
Set the specification number of the input/output device corresponding
to I/O CHANNEL=1.
0113 Baud rate (when I/O CHNNEL is set to 1)
[Input type] Parameter input
[Data type] Byte
[Valid data range] 1 to 12
Set the baud rate of the input/output device corresponding to I/O
CHANNEL=1.