4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 354 -
4.46 PARAMETERS OF ROTARY TABLE DYNAMIC FIXTURE
OFFSET
#7 #6 #5 #4 #3 #2 #1 #0
7570 CFA FTP
[Input type] Parameter input
[Data type] Bit path
# 0 FTP Fixture offset type setting
0: Movement type
(The tool moves when the fixture offset changes.)
1: Shift type
(The tool does not move when the fixture offset changes.)
# 3 CFA When the fixture offset function is used, and a rotation axis is
specified in the increment mode (G91 mode) after manual intervention
in the state where the manual absolute switch is on:
0: A vector calculation is made using coordinates not reflecting a
manual intervention amount.
1: A vector calculation is made using coordinates reflecting a
manual intervention amount.
#7 #6 #5 #4 #3 #2 #1 #0
7575
FAX
[Input type] Parameter input
[Data type] Bit axis
# 0 FAX Fixture offset on each axis is:
0: Disabled.
1: Enabled.
7580
Rotation axis for fixture offset (first group)
7581
Linear axis 1 for fixture offset (first group)
7582
Linear axis 2 for fixture offset (first group)
7583
Rotation axis for fixture offset (second group)
7584
Linear axis 1 for fixture offset (second group)