B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 401 -
operation:
When the emergency stop signal is turned off, the relevant path is
determined and operation is performed so that the emergency
stop signal is virtually turned off for the determined path.
When the servo-off signal is turned on, the relevant axis is
determined and operation is performed so that the servo-off
signal is virtually turned on for the determined axis.
When a servo alarm is issued, the relevant axis is determined and
the alarm “SV0003 CONTINUATION OF SYNCHRONOUS
OR COMPOSITE CONTROL DISABLED” is issued for the
determined axis to stop moving the tool along the axis. When
bit 2 (SVF) of parameter No. 8168 is set to 1, this servo-off
specification follows the SVF setting.
NOTE
This setting is valid also during operation. For all
axes placed under synchronous or composite
control, the emergency stop signal is turned off, the
servo-off signal is turned on, or a servo alarm is
issued.
# 2 SVF When an axis under composite control is placed in the servo-off state:
0: Composite control is canceled.
1: Composite control is not canceled.
Follow-up specification follows the setting of bit 0 (FUPx) of
parameter No. 1819.
When bit 2 (SVF) of parameter No. 8168 is set to 1, bit 0 (NMR) of
parameter No. 8161 is invalid. Bit 1 (MSO) of parameter No. 8168,
specification for servo-off, is also invalid.
NOTE
If a composite control axis is placed in the servo-off
state when stopped, set this parameter to 1.
#7 #6 #5 #4 #3 #2 #1 #0
8169 MDMx
[Input type] Parameter input
[Data type] Bit axis
# 0 MDMx As machine coordinates in composite control:
0: Coordinates for the local path are displayed.
1: Coordinates for the other path in composite control are displayed.
8180 Master axis with which an axis is synchronized under synchronous control
[Input type] Parameter input
[Data type] Word axis