B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 497 -
13626 Maximum cutting speed when AI contour control is used (precision level 1)
13627 Maximum cutting speed when AI contour control is used (precision level 10)
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Each of these parameters sets a maximum cutting speed in AI contour
control. Set a value (precision level 1) with emphasis placed on speed,
and a value (precision level 10) with emphasis on precision.
13628
Parameter number corresponding to arbitrary item 1 when AI contour control
is used
13629
Parameter number corresponding to arbitrary item 2 when AI contour control
is used
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 1 to 65535
These parameters set the parameter numbers corresponding to
arbitrary items 1 and 2.
NOTE
The parameter numbers corresponding to the
following cannot be specified:
- Bit parameters
- Spindle parameters (No. 4000 to No. 4799)
- Parameters of real number type
- Parameters that require power-off (for which the
alarm (PW0000) is issued)
- Nonexistent parameters