B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 327 -
6254 ε value on the X axis during automatic tool compensation (T series)
ε value during automatic tool length measurement (M series) (for the XAE1
and GAE1 signals)
6255 ε value on the Z axis during automatic tool compensation (T series)
ε value during automatic tool length measurement (M series) (for the XAE2
and GAE2 signals)
6256
ε value during automatic tool length measurement (M series) (for the XAE3
and GAE3 signals)
[Input type] Parameter input
[Data type] 2-word path
[Unit of data] mm, inch, deg (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
These parameters set the relevant ε value during automatic tool
compensation (T series) or automatic tool length measurement (M
series).
NOTE
1 For the M series, when the setting of
parameter No. 6255 or 6256 is 0, the setting
of parameter No. 6254 is used.
2 Set a radius value regardless of whether
diameter or radius programming is specified.
6281 Feedrate for the skip function (G31)
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
This parameter sets a feedrate for the skip function (G31). This
parameter is valid when bit 1 (SFP) of parameter No. 6207 is set to 1.
NOTE
For the multi-stage skip function and high-speed
skip, see the description of parameter No. 6282 to
No. 6285.