4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 28 -
4.5 PARAMETERS OF READER/PUNCHER INTERFACE
To transfer data (programs, parameters, and so forth) to and from an
external input/output device through the I/O device interface
(RS-232-C serial interface), the parameters described below need to
be set.
The input/output device connected to a channel (such as RS-232-C
serial port 1 and RS-232-C serial port 2) can be selected by setting I/O
CHANNEL (parameter No. 0020). The specifications (input/output
specification number, baud rate, and the number of stop bits) of an
input/output device connected to each channel must be set in the
parameters corresponding to each channel beforehand.
For channel 1, two combinations of parameters to specify the
input/output device data are provided.
The following shows the interrelation between the input/output device
interface parameters for the channels.
I/O CHANNEL
or foreground input
Set channels to be used
for data input/output.
I/O CHANNEL (0 to 5)
=0 : Channel 1
=1 : Channel 1
=2 : Channel 2
=3 : Channel 3
:
:
:
Input/output to and from the memor
card interface, etc. is also possible.
When IO4 is set
Foreground output
Background input
Background input
The channel setting is the same as
No.0020.
Input/output channel number (parameter No.0020)
↓
0101 Stop bit and other data
I/O CHANNEL=0 0102 Number specified for the input/output device
0103 Baud rate
0111 Stop bit and other data
I/O CHANNEL=1 0112 Number specified for the input/output device
0113 Baud rate
0121 Stop bit and other data
I/O CHANNEL=2 0122 Number specified for the input/output device
0123 Baud rate
:
:
:
I/O CHANNEL=5
(Channel 1)
(Channel 1)
(Channel 2)
0020
0021
0022
0023