4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 30 -
0024
Setting of communication with the ladder development tool (FANUC
LADDER-III, ladder editing package)
[Input type] Setting input
[Data type] Word
[Valid data range] 0 to 255
This parameter is used to enable or disable the PMC online connection
function.
By specifying this parameter, the PMC online connection function can
be enabled or disabled without displaying the PMC online setting
screen.
Setting RS-232-C High-speed interface
0 The setting on the PMC online setting screen is not altered.
1 To be used (channel 1) Not to be used
2 To be used (channel 2) Not to be used
10 Not to be used To be used
11 To be used (channel 1) To be used
12 To be used (channel 2) To be used
255 Communication is terminated forcibly (as with the [FORCED
STOP] soft key).
NOTE
1 The setting of this parameter becomes valid when
the power is turned on or this parameter is
modified. After this parameter is set, the power
need not be turned off then back on.
2 A setting modification made on the PMC online
setting screen is not reflected in this parameter.
3 The communication settings of a baud rate and so
forth for using RS-232-C made on the PMC online
setting screen are valid. When no modification is
ever made to the settings on the PMC online
setting screen, the baud rate is 9600, parity is not
used, and the number of stops bits is 2.
#7 #6 #5 #4 #3 #2 #1 #0
0100 ENS IOP NCR CRF CTV
[Input type] Setting input
[Data type] Bit
# 1 CTV Character counting for TV check in the comment section of a
program.
0: Performed
1: Not performed
# 2 CRF Output of the end of block (EOB) in ISO code
0: Depends on the setting of bit 3 (NCR) of parameter No. 100.
1: CR, LF are output.