4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 284 -
4.24 PARAMETERS OF SINGLE DIRECTIONAL POSITIONING
#7 #6 #5 #4 #3 #2 #1 #0
5431 PDI MDL
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 MDL The G60 code (one-direction positioning) is:
0: One-shot G code (group 00).
1: Modal G code (group 01).
# 1 PDI In the G60 mode, an in-position check at a stop position is:
0: Not made.
1: Made.
5440 Positioning direction and overrun distance in single directional positioning
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] -32767 to 32767
This parameter sets the positioning direction and overrun distance in
single directional positioning (G60) for each axis. The positioning
direction is specified using a setting data sign, and the overrun
distance using a value set here.
Overrun distance>0: The positioning direction is positive (+).
Overrun distance<0: The positioning direction is negative (*).
Overrun distance=0: Single directional positioning is not performed.