5.COMPILATION AND DECOMPILATION B-66234EN/05
- 238 -
5.5 AUTOMATIC NUMBERING OF TMRB/ TMRBF/ DIFU/ DIFD
If you use this function, the 1st parameter for the TMRB/ TMRBF/
DIFU/ DIFD instructions will be automatically numbered at the
compiling process and you no longer have to take care of entering the
specific numbers for these parameters.
Supported PMC models
Supported
30i/31i/32i-A Extended function
30i/31i/32i-A
Supported instructions
The 1st parameter of the following functional instructions is the target
of assignment.
SUB24(TMRB)
SUB77(TMRBF)
SUB57(DIFU)
SUB58(DIFD)
To use this function, you should set the 1st parameter for the TMRB/
TMRBF/ DIFU/ DIFD instructions to 0. When the TMRB/ TMRBF/
DIFU/ DIFD instructions, that have a number 0 in the first parameter,
are detected in the compiling process of the FANUC LADDER-III,
their numbers are automatically generated from the last number. In
this case, the TMRB/ TMRBF/ DIFU/ DIFD instructions, that have a
number except 0, is detected, its number is not changed. This
automatic number generation is done only at the compiling process of
FANUC LADDER-III. Therefore, you can set its number to 0 in a
mnemonic file or on the offline editing screen but you cannot set its
number to 0 on the online editing screen which does not executes the
compiling process.
RD Input
TMRB
0
1000
WRT Output1
RD Input
TMRBF
0
1000
WRT Output2
RD Input
DIFU
0
WRT Output3
RD Input
DIFD
0
WRT Output4
Fig. 5.5(a) Ladder diagram Fig. 5.5(b) Mnemonic data