9.DIAGNOSIS B-66234EN/05
- 330 -
9.3.6.3 Setting items
• HIDE PMC PROGRAM (PMC-SB7: K900.0, PMC-SA1: K17.0)
Not checked : Displays sequence programs.
Checked : Hides sequence programs.
• PROGRAMMER ENABLE (PMC-SB7: K900.1, PMC-SA1:
K17.1)
Not checked : Disables built-in programmer functions.
Checked : Enables built-in programmer functions.
• LADDER MANUAL START (PMC-SB7: K900.2, PMC-SA1:
K17.2)
Not checked : After the power is turned on, sequence programs
will be automatically executed.
Checked : Sequence programs will be executed with the
sequence program execution soft key.
• RAM WRITE ENABLE (PMC-SB7: K900.4, PMC-SA1: K17.4)
Not checked : Disables the forcing and overwrite functions.
Checked : Enables the forcing and overwrite functions.
• SIGNAL TRACE START (PMC-SB6: K900.5)
Not checked : The signal trace function starts tracing with the
trace execution button.
Checked : The signal trace function automatically starts
tracing after the power is turned on.
• SIGNAL ANALYSIS START (PMC-SB6: K900.6)
Not checked : The signal waveform display function starts
sampling with the execution button.
Checked : The signal waveform display function
automatically starts sampling after the power is
turned on.
• HIDE DATA TBL CNTL SCREEN (PMC-SB7: K900.7,
PMC-SA1: K17.7)
Not checked : Displays the PMC parameter data table control
screen.
Checked : Hides the PMC parameter data table control
screen.
• SIGNAL TRIGGER START (PMC-SB7: K901.2, PMC-SA1:
K18.8)
Not checked : The trigger stop function does not automatically
starts when the power is turned on.
Checked : The trigger stop function automatically starts
when the power is turned on.
• EDIT ENABLE (PMC-SB7: K901.6, PMC-SA1: K18.6)
Not checked : Disables sequence program editing.
Checked : Enables sequence program editing.