13.ERROR MESSAGES B-66234EN/05
- 466 -
13.2.12 Online
Error code Message Cause/action
N:E-3001 Flash ROM Write error
The F-ROM is abnormal. Replace the F-ROM.
Contact your FANUC service center.
N:E-3002 Flash ROM Read error
N:E-3003 Flash ROM Erase error
The F-ROM is abnormal. Replace the F-ROM.
Contact your FANUC service center.
N:E-3004 Flash ROM Area error
N:E-3005 Flash ROM Program nothing
N:E-3006 Flash ROM Size error
A sequence program is larger than the F-ROM. Increase
the size of the F-ROM.
Try the CONDENCE function, which is an offline function.
N:E-3007 Flash ROM Not EMG stop
The CNC is not placed in the emergency stop state. Place
the CNC in the emergency stop state.
N:E-3008 Flash ROM Program data error
A sequence program on the PMC is destroyed. Reenter the
sequence program.
N:E-3009 Flash ROM Access request error
N:E-3011 User C program error occurs on PMC.
N:E-3012 Flash ROM Another used
N:E-3013 Flash ROM Command error
N:E-3014 Flash ROM No space
N:E-3015 Flash ROM File error
N:E-3016 Flash ROM File not match
N:E-3017 Flash ROM Un-known F-ROM
N:E-3018 Flash ROM I/O error
N:E-3019 Flash ROM Undefine error code
N:E-3300 Signal trigger unavailable
The user switched from online editing to the signal trigger
stop function.
N:E-3302 Reject Signal trigger
The user switched to online editing during signal trigger
execution.
N:E-3307 Cannot be changed Signal trigger is executing
The user attempted to modify parameter settings during
signal trigger execution.
N:E-3390 Program is running
N:E-3410 Function param is out of range
N:E-6000 Signal Analysis function is not supported
The PMC is of a type that does not support the signal
analysis function.
N:E-6001 Signal Trace function is running
During signal trace function execution, the signal analysis
function cannot be executed.
N:E-6002 Address Error A specified address is invalid.
N:E-6003 No Trigger Address
When the condition is <Trigger-ON> or <Trigger-OFF>, set
a trigger address.
N:E-6004 [About]/[Before] is illegal on [Start] selected
When the condition is <Start>, <About> and <Before>
cannot be selected as a trigger mode.
N:E-6005 No Signal Address No sampling address is set.
N:E-6006 Sampling Time Error: An invalid sampling time is set.
N:E-6041 The communication to PMC is not ready The connection with the NC is disconnected.