6. Click <Log File> button. Then, the result of the multiple address
replace is displayed.
#### LADDER ####
LEVEL1
Net1 Y0000.0 => R0000.0
LEVEL2
Net1 Y0000.0 => R0000.0
Net1 Y0000.0 => R0000.0
Net12 Y0126.0 => X0000.0
Error: Net13 Y0126.0 => X0000.0 This address is read-only.
Error count = 000001
#### SYMBOL ####
GLOBAL
Y0000.0 => R0000.0 y0_BOOL
Y0000.0 => R0000.0
Y0000 => R0000
Y0000 => R0000
Y0000 => R0000
LEVEL1
Y0000.0 => R0000.0 y0_BOOL2
Y0000 => R0000 y0_BYTE
Error: Y0000.0 => R0000.0 This address overlaps.(y0_BOOL2)
Error: Y0000 => R0000 This address overlaps.()
Error: Y0000 => R0000 This address overlaps.()
Error: Y0000 => R0000 This address overlaps.(y0_BYTE)
Error count = 000004
*** Multiple address replace completed ***
Program Name:30i-A.LAD
PMC Name :30i-A PMC(MEM-B,EXT)
Replace date:Wednesday, May 18, 2005 5:50:27 PM
Fig. 3.5.24.1(k)
Note
1. The multi-replace of the step sequence is not supported.
2. The content of the address display window is not saved. When the ladder program is
closed or other ladder programs are opened, the setting is lost.
3. L address and P address can not be replaced by the multi-replace.
4. The multi-replace can not be used in the online mode. Please use it in offline mode.
5. When the multi-replace is executed for the ladder program to which the partial
protect is set, the address of a global symbol is replaced. Please use this function
after confirming that the address of a global symbol is not included in the replace
address.
6. The automatic assignment is released when the address of the automatic
assignment is replaced, and the address of the symbol is decided.