B-66234EN/05 13.ERROR MESSAGES
- 449 -
Error code Message Cause/action
E:E-6054 COM FUNCTION MISSING
The method of using function instruction COM (SUB9) is
incorrect. Check that COM is paired with COME (SUB29)
correctly.
E:E-6055 JUMP FUNCTION MISSING
The method of using function instruction JMP (SUB10) is
incorrect. Check that JMP is paired with IMPE (SUB30)
correctly.
E:E-6056 END FUNCTION MISSING
Function instructions END1, END2, END3, and END are
incorrect. Check that the order of END1, END2, END3, and
END is correct.
E:E-6057 PROGRAM NOTHING
E:E-6058 LADDER BROKEN
A ladder is destroyed, so that it cannot be updated.
Reenter the ladder.
E:E-6059 COIL NOTHING
E:E-6060 CALL CALLU FUNCTION MISSING
Function instructions CALL and CALLU are incorrect.
Create function instructions CALL and CALLU on the
second level of a ladder or in a sub-program.
E:E-6061 COM FUNCTION MISSING (CALL SP)
Function instruction CALL or CALLU is found between
function instructions COM (SUB9) and COME.
CALL and CALLU cannot be created between COM and
COME.
E:E-6062 JMP FUNCTION MISSING (SP)
The method of using function instruction JMP (SUB10) in a
sub-program is incorrect. Check that JMP is correctly
paired with JMPE (SUB30).
E:E-6063 SUB PROGRAM MISSING
The method of using function instruction SP is incorrect.
Check that SP is paired with SPEED correctly.
E:E-6064 SP NO. DUPLICATE
The same sub-program number already exists.
Change the sub-program number.
E:E-6065 SUB PROGRAM NOTHING Create a sub-program.
E:E-6066 END FUNCTION NOTHING Add the END instruction.
E:E-6067 SP FUNCTION MISSING
E:E-6068 LBL COUNT OVER Reduce the number of labels.
E:E-6069 LBL NO. DUPLICATE
The same label number already exists.
Change the label number.
E:E-6070 LBL FUNCTION NOTHING (JMPB)
Function instruction LBL specified by JMPB is not found.
Add the LBL function instruction.
E:E-6071 COM FUNCTION MISSING (JMPB)
Function instruction JMPB is found between function
instructions COM and COME. No jump can be made
beyond COM and COME. Ensure that JMPB is not inserted
between COM and COME. Alternatively, also create
specified function instruction LBL between COM and
COME.
E:E-6072 JMPB FUNCTION MISSING
The JMPB instruction allows a jump to be made to a
sub-program only. Ensure that a jump is made to a point
within a sub-program.
E:E-6073 LBL FUNCTION NOTHING (JMPC)
Function instruction LBL, specified by JMPC, is not found.
Add function instruction LBL.
E:E-6074 COM FUNCTION MISSING (LBL)
Specified function instruction LBL is found between
function instructions COM and COME. A jump cannot be
made to a point between COM and COME. Ensure that
LBL is not inserted between COM and COME.
Alternatively, also create function instruction JMPC
between COM and COME.