4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 108 -
NOTE
1 This parameter is valid only for axes of rotation axis
A type.
2 For axes of rotation axis A type that use a scale
having no speed data, be sure to set this
parameter.
3 When you have changed this parameter, establish
the reference position again.
#7 #6 #5 #4 #3 #2 #1 #0
TANx SCPx
1817
TANx SCPx SCRx
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Bit axis
SCRx When rotation axis B type is set for an axis for which a scale not
having speed data is used, scale data conversion is:
0 : Not performed.
1 : Performed.
NOTE
1 This parameter is valid only for axes of rotation axis
B type.
2 When there is no discontinuous point in scale data
within the movable range of a rotation axis, do not
set this parameter for the axis even if the axis is of
rotation axis B type.
3 When you have changed this parameter, establish
the reference position again.
SCPx When bit 2 (DC2) of parameter No. 1802 is set to 1, the zero point of
an encoder with absolute address reference marks (linear scale or
rotary encoder) is located:
0 : On the negative side.
(The reference position is located on the positive side when viewed
from the encoder zero point.)
1 : On the positive side.
(The reference position is located on the negative side when viewed
from the encoder zero point.)