4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 26 -
0204 Remote diagnosis channel
[Data type] Byte
[Valid data range] 0, 1, 2
The interface to be used for remote diagnosis is:
0,1 : RS-232-C serial port 1 (channel 1).
2 : RS-232-C serial port 2 (channel 2).
0211 Password 1 for remote diagnosis
0212 Password 2 for remote diagnosis
0213 Password 3 for remote diagnosis
[Data type] 2-word
[Valid data range] 1 to 99999999
Specify a password for using the remote diagnosis function.
The remote diagnosis function has the following password settings.
Data can be protected by preventing a third party from accessing any
system parameter or machining program without permission.
Password 1:
Set a password for the whole service of the remote diagnosis
function. (The whole remote diagnosis service is available only
when this password is input on the host side (PC, for instance).)
Password 2:
Set a password of a part program. (The input/output, verification,
and the like of a program are possible only when this password is
input on the host side (PC, for instance).)
Password 3:
Set a password of a parameter. (The input/output or the like of a
parameter is possible only when this password is input on the
host side (PC, for instance).)
NOTE
Once any value other than 0 is specified as a
password, the password can be changed only
when the same value is specified in the
corresponding keyword (parameters No. 221 to No.
223). If any value other than 0 is specified as a
password, the password setting is not displayed on
the parameter screen (blank display is provided).
Take great care when setting the password.
0221 Keyword 1 for remote diagnosis
0222 Keyword 2 for remote diagnosis