B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 373 -
4.51 PARAMETERS OF FAILURE DIAGNOSIS
#7 #6 #5 #4 #3 #2 #1 #0
8850 MDG
[Data type] Bit
MDG The failure diagnosis function is:
0 : Enabled.
1 : Disabled.
#7 #6 #5 #4 #3 #2 #1 #0
8853 TS8 TS7 TS6 TS5 TS4 TS3 TS2 TS1
[Data type] Bit
TS8 to TS1 For the thermal simulation data for each servo axis:
0 : Failure prediction is not performed.
1 : Failure prediction is performed. (Set a prediction level in
parameter No. 8860.)
#7 #6 #5 #4 #3 #2 #1 #0
8854 TR8 TR7 TR6 TR5 TR4 TR3 TR2 TR1
[Data type] Bit
TR8 to TR1 For the disturbance load torque value for each servo axis:
0 : Failure prediction is not performed.
1 : Failure prediction is performed. (Set a prediction level in
parameter No. 8861.)
8860 Failure prediction level of thermal simulation data
[Data type] Word axis
[Unit of data] %
[Valid data range] 0 to 100
8861 Failure prediction level of disturbance load torque
[Data type] Word axis
[Unit of data] %
[Valid data range] 0 to 100