4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 204 -
P code for selecting the first spindle in multi-spindle control
3781
P code for selecting the second spindle in multi-spindle control
3782
P code for selecting the third spindle in multi-spindle control
3783
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Word
[Valid data range] 0, 1 to 32767
If bit 3 (MPP) of parameter No. 3703 is set to 1, set the P code to
select each spindle under multi-spindle control. Specify the P code in
a block containing the S command.
Example)
If the P code value for selecting the second spindle is set to 3,
S1000 P3;
causes the second spindle to rotate at S1000.
NOTE
1 This parameter is valid if bit 3 (MPP) of parameter
No. 3703 is set to 1.
2 If this parameter is set to 0, the corresponding
spindle cannot be selected by a P code.
3 Identical P code values cannot be used for different
spindles.
4 If this parameter is used (bit 3 (MPP) of parameter
No. 3703 is set to 1), signals SWS1 to SWS3
<G027 bits 0 to 2> become invalid.
5 To use this parameter, the multi-spindle control
function is needed.