4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 386 -
#7 #6 #5 #4 #3 #2 #1 #0
13112 SPI SVI IDW
[Data type] Bit
IDW Editing on the servo information screen or spindle information screen
is
0 : Prohibited.
1 : Not prohibited.
SVI Servo information screen is
0 : Displayed.
1 : Not displayed.
SPI Spindle information screen is
0 : Displayed.
1 : Not displayed.
13150 Number of sets of offset data displayed on the offset screen
[Data type] Word
[Valid data range] 0, 1 to the maximum sets of tool offset data
This parameter sets the number of sets of offset data to be displayed
on the offset screen.
NOTE
1 When this parameter is set, the power must be
turned off before operation is continued.
2 If 0 or a value beyond the data range is set in this
parameter, the setting of this parameter becomes
invalid, and all offset data is displayed.