8311 Axis number of master axis in synchronous control
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Byte axis
<For the T series>
[Valid data range] 0 to (Number of controlled axes - 1)
Select a master axis and slave axis in simple synchronous control. Set
a master axis number with a slave axis. For the parameters for the first
axis through the fourth axis of parameter No.8311, set the following:
Units digit of the parameter for the first axis →
Set the axis number of the master axis when the first axis is used
as the slave axis.
Tens digit of the parameter for the first axis →
Set the axis number of the master axis when the second axis is
used as the slave axis.
Units digit of the parameter for the second axis →
Set the axis number of the master axis when the third axis is used
as the slave axis.
Tens digit of the parameter for the second axis →
Set the axis number of the master axis when the fourth axis is
used as the slave axis.
Units digit of the parameter for the third axis →
Always set to 0.
Tens digit of the parameter for the third axis →
Always set to 0.
Units digit of the parameter for the fourth axis →
Always set to 0.
Tens digit of the parameter for the fourth axis →
Always set to 0.
Number Tens digit Units digit
No.8311 : First axis Second axis First axis
No.8311 : Second axis Fourth axis Third axis
Note that the axis number settings are as follows:
0 -> First axis, 1 -> Second axis, 2 -> Third axis, 3 -> Fourth axis
Example:
To use the third axis as the master axis and the fourth axis as the
slave axis, set the axis number (setting of 2) of the third axis
(master axis) in the tens digit for the second axis in the fourth
axis (slave axis) parameter, that is, parameter No. 8311.
No. 8311 First: 00
Second: 20
Third: 00
Fourth: 00