B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 19 -
0103 Baud rate (when the I/O CHANNEL is set to 0)
[Data type] Byte
Set baud rate of the input/output device used when the I/O
CHANNEL is set to 0, with a set value in Table 4.2.2 (b).
Table 4.2.2 (b)
Set value Baud rate (bps) Set value Baud rate (bps)
1 50 7 600
2 100 8 1200
3 110 9 2400
4 150 10 4800
5 200 11 9600
6 300
12 19200
4.2.3 Parameters of Channel 1 (I/O CHANNEL=1)
#7 #6 #5 #4 #3 #2 #1 #0
0111 NFD ASI SB2
[Data type] Bit
These parameters are used when I/O CHANNEL is set to 1. The
meanings of the bits are the same as for parameter 0101.
0112 Number specified for the input/output device (when I/O CHANNEL is set to 1)
[Data type] Byte
Set the number specified for the input/output device used when
the I/O CHANNEL is set to 1, with one of the set values listed in
Table 4.2.2 (a).
0113 Baud rate (when I/O CHNNEL is set to 1)
[Data type] Byte
Set the baud rate of the input/output device used when I/O
CHANNEL is set to 1, with a value in Table 4.2.2 (b).
4.2.4 Parameters of Channel 2 (I/O CHANNEL=2)
#7 #6 #5 #4 #3 #2 #1 #0
0121 NFD ASI SB2
[Data type] Bit
These parameters are used when I/O CHANNEL is set to 2. The
meanings of the bits are the same as for parameter 0101.
0122 Number specified for the input/output device (when I/O CHANNEL is set to 2)
[Data type] Byte