4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 48 -
1240
Coordinate value of the first reference position on each axis in the machine
coordinate system
1241
Coordinate value of the second reference position on each axis in the
machine coordinate system
1242
Coordinate value of the third reference position on each axis in the machine
coordinate system
1243
Coordinate value of the fourth reference position on each axis in the
machine coordinate system
NOTE
When these parameters are set, power must be
turned off before operation is continued.
[Data type] 2-word axis
[Unit of data]
Increment system IS-A IS-B IS-C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] -99999999 to 99999999
Set the coordinate values of the first to fourth reference
positions in the machine coordinate system.
1260 Amount of a shift per one rotation of a rotation axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] 2-word axis
[Unit of data]
Increment system Unit of data Standard value
IS-A 0.01 deg 36000
IS-B 0.001 deg 360000
IS-C 0.0001 deg 3600000
[Valid data range] 1000 to 99999999
Set the amount of a shift per one rotation of a rotation axis.
For the rotation axis used for cylindrical interpolation, set the standard
value.