4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 10 -
4.1 PARAMETERS OF SETTING
#7 #6 #5 #4 #3 #2 #1 #0
0000 SEQ INI ISO TVC
Setting entry is acceptable.
[Data type] Bit
TVC TV check
0 : Not performed
1 : Performed
ISO Code used for data output
0 : EIA code
1 : ISO code
INI Unit of input
0 : In mm
1 : In inches
SEQ Automatic insertion of sequence numbers
0: Not performed
1: Performed
When a program is prepared by using MDI keys in the part program
storage and edit mode, a sequence number can automatically be
assigned to each block in set increments. Set the increment to
parameter 3216.
#7 #6 #5 #4 #3 #2 #1 #0
0001 FCV
Setting entry is acceptable.
[Data type] Bit
FCV Tape format
0: Series 0 standard format
(Series 16/18 compatible format)
1: Series 10 / 11 format
NOTE
Programs created in the Series 10 / 11 tape format
can be used for operation on the following functions:
1 Subprogram call M98
2 Thread cutting with equal leads G32 (T series)
3 Canned cycle G90, G92, G94 (T series)
4 Multiple repetitive canned cycle G71 to G76 (T
series)
5 Drilling canned cycle G73, G74, G76, G80 to G89
(M series)
6 Cutter compensation C (M series)
2 When the tape format used in the Series 10/11 is
used for this CNC, some limits may add. Refer to the
Series 0i/0i Mate-MODEL C OPERATOR'S MANUAL.