B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 377 -
12350 Manual handle feed magnification m
[Data type] Word axis
[Unit of data] 1
[Valid data range] 0 to 127
This parameter sets the magnification to be used for each axis when
manual handle feed movement amount select signal MP1 <G019#4>
is set to 0, and MP2 <G019#5> is set to 1.
If this parameter is set to 0 for a target axis for movement, the setting
of parameter No. 7113 applies.
12351 Manual handle feed magnification n
[Data type] Word axis
[Unit of data] 1
[Valid data range] 0 to 1000
This parameter sets the magnification to be used for each axis when
manual handle feed movement amount select signal MP1 <G019#4>
is set to 1, and MP2 <G019#5> is set to 1.
If this parameter is set to 0 for a target axis for movement, the setting
of parameter No. 7114 applies.
Movement amount select signal
MP2 MP1
Movement amount (manual handle
feed or manual handle interrupt)
0 0 Least input increment × 1
0 1 Least input increment × 10
1 0 Least input increment × m
1 1 Least input increment × n