B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 139 -
#7 #6 #5 #4 #3 #2 #1 #0
3006 EPS EPN GDC
GDC As the deceleration signal for reference position return:
0 : X009 is used.
1 : G196 is used. (X009 is disabled.)
EPN Workpiece number search signals are assigned to:
0 : PN1, PN2, PN4, PN8, and PN16 <G009>.
1 : EPN0 to EPN13 <G024, G025>.
EPS When a program is searched using the workpiece number search
function, it is started by:
0 : Automatic operation start signal ST (when automatic operation
(memory operation) is started).
1 : Workpiece number search start signal EPNS <G025#7>. (Search
is not started by ST.)
#7 #6 #5 #4 #3 #2 #1 #0
3008 XSG
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
XSG The signals assigned to X addresses are:
0 : Fixed to these addresses.
1 : Able to be re-assigned to any addresses. (Emergency stop signal
*ESP <X008#4>, however, cannot be changed.)
When assignment to any addresses is selected, set parameter Nos.
3012 to 3014.
3010 Time lag in strobe signals MF, SF, TF, and BF
[Data type] Word
[Unit of data] 1 ms
[Valid data range] 16 to 32767
The time required to send strobe signals MF, SF, TF, and BF after the
M, S, T, and B codes are sent, respectively.
M, S, T, B code
MF, SF, TF, BF, signal
Delay time
Fig.4.19 (a) Delay Time of the strobe signal