B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 49 -
1280
First address of the signal group used by the external machine zero point
shift extension
[Data type] Word
[Valid data range] 0 to 65535
Set the first address of the signal group used by the external machine
zero point shift extension. If 100 is specified, R0100 to R0115 can be
used.
R0100
Shift amount of external machine zero point shift extension for the
first axis (LOW)
R0101
Shift amount of external machine zero point shift extension for the
first axis (HIGH)
R0102
Shift amount of external machine zero point shift extension for the
second axis (LOW)
R0103
Shift amount of external machine zero point shift extension for the
second axis (HIGH)
: :
R0114
Shift amount of external machine zero point shift extension for the
eighth axis (LOW)
R0115
Shift amount of external machine zero point shift extension for the
eighth axis (HIGH)
NOTE
1 If the specified number is not present, the external
machine zero point shift extension is disabled.
2 A shift amount of the external machine zero point
shift extension can be written from the macro
executer.
3 This parameter is valid when bit 0 (EMC) of
parameter No. 1203 is set to 1.
1290 Distance between two opposite tool posts in mirror image
[Data type] 2-word
[Unit of data]
Increment system IS-A IS-B IS-C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
[Valid data range] 0 to 99999999
Set the distance between two opposite tool posts in mirror image.