B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 163 -
1 : Used.
#7 #6 #5 #4 #3 #2 #1 #0
3207 OM4
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Bit
OM4 A message displayed on the external operator message screen can
have:
0 : Up to 256 characters, and just a single message can be displayed.
1 : Up to 64 characters, and up to four messages can be displayed.
#7 #6 #5 #4 #3 #2 #1 #0
3208 COK SKY
[Data type] Bit
SKY The function key [SYSTEM] on the MDI panel is:
0 : Enabled.
1 : Disabled.
COK The automatic screen erase function is:
0 : Enabled.
1 : Disabled.
NOTE
If this parameter is set to 1, manual screen erasure
by the CAN + FUNCTION key is enabled,
irrespective of the setting of parameter No. 3123.
#7 #6 #5 #4 #3 #2 #1 #0
3209 UPP NFU MPD
[Data type] Bit
MPD When a subprogram is executed, the main program number is:
0 : Not displayed.
1 : Displayed.
NFU In the screen erase function/automatic screen erase function, when the
function key is pressed to erase or display a screen, switching of
screen with the function key is:
0 : Performed.
1 : Not performed.
UPP The FOCAS1/ETHERNET cnc_upload3( ) function:
0 : Does not upload the protected programs.
1 : Uploads the protected programs if a search is possible.
3210 Password
[Data type] 2-word axis