4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 156 -
3131 Subscript of each axis name
[Data type] Byte axis
This parameter specifies a subscript (one character) of each axis name
with a code.
The subscript (one character) specified in this parameter is displayed
following the axis name.
NOTE
For characters and codes, see the correspondence
table in Appendix A.
[Example]
When the axes include X, Z, C, and Y, and the following settings
are made, the axis names are displayed as XA, Z1, CS, and Y1:
Parameter 3131x 65 (A)
Parameter 3131z 49 (1)
Parameter 3131c 83 (S)
Parameter 3131y 49 (1)
Axis name (absolute coordinate) for current position display
3132
Axis name (relative coordinate) for current position display
3133
[Data type] Byte axis
[Valid data range] 0 to 255
These parameters set the axis name for current position display.
When G code system B or C is used, the axis name set in parameter
No.3132 is used for both absolute and relative coordinate axes.
The values set in these parameters are used only for display.
For a command address, the axis name set in parameter No.1020 is
used.
When 0 is specified in these parameters, the value set in parameter
No.1020 is used.
3134
Axis display order on workpiece coordinate system screen and workpiece
shift screen
[Data type] Byte axis
[Valid data range] 0, 1 to the number of controlled axes
This parameter specifies the order in which axes are displayed on the
workpiece coordinate system screen and workpiece shift screen (for T
series).
When the parameters of all axes are set to 0, all axes are displayed.
When the parameters of some axes are set, the axes for which a value
of 0 is specified do not appear. The displayed axes are consecutive
without spaces being left for non-displayed axes.