B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 147 -
SMF During simplified synchronous control, movement along a slave axis
is: (see the parameter No.8311)
0 : Included in the actual speed display
1 : Not included in the actual speed display
#7 #6 #5 #4 #3 #2 #1 #0
OHS SOV OPH SPD GPL
3106
OHS SOV OPH GPL
[Data type] Bit
GPL On the program list screen, the list-by-group function is:
0 : Disabled
1 : Enabled
SPD Names for actual spindle speed values are displayed:
0 : Regardless of the selected spindle position coder (in second
position coder selection signal (PC2SLC))
1 : Depending of the selected spindle position coder (in second
position coder selection signal (PC2SLC))
SPD=0 SPD=1
Spindles 1 and 2 Spindles 1 Spindles 2
S S1 S2
SACT
ACT, S
SACT1 SACT2
OPH The operation history screen is:
0 : Not displayed.
1 : Displayed.
SOV The spindle override value is:
0 : Not displayed.
1 : Displayed.
NOTE
This parameter is enabled only when bit 2 (DPS) of
parameter No.3105 is set to 1.
OHS Operation history sampling is:
0 : Performed.
1 : Not performed.
NOTE
Normally, set 0 (sampling is performed).
#7 #6 #5 #4 #3 #2 #1 #0
3107 MDL SOR REV DNC
[Data type] Bit
DNC Upon reset, the program display for DNC operation is:
0 : Not cleared
1 : Cleared