9. IMPROVEMENT OF ADDING
THE NUMBER OF THREAD
SPARK–OUT OPERATIONS
TO THE NUMBER OF CUTS
B–63284EN/03
ADDITIONAL FUNCTIONS OF SERIES
BH0M/BH1D/BH2D, BH1E/BH2E/BH3E,
AND BH1F/BH2F/BH3F
602
When the data item SPARK OUT in thread process data is altered, the new
SPARK OUT value is reflected in the number of cuts in threading. This
function is made available by parameter setting.
When SPARK OUT in thread process data is altered, the new value is
reflected in the number of cuts in threading. Depending on the conditions
before and after the alteration of the SPARK OUT data, the number of cuts
is treated as follows:
(1) When the entered SPARK OUT data is the same as the original data
The number of cuts remains unchanged.
(2) When the entered SPARK OUT data is greater than the original data
The number of cuts = original number of cuts + increase in SPARK
OUT
(3) When the entered SPARK OUT data is smaller than the original data
a) When the original number of cuts is greater than or equal to the
entered data
The number of cuts = original number of cuts – decrease in
SPARK OUT
b) When the original number of cuts is smaller than the entered data
The number of cuts = entered data (SPART OUT)
This function is enabled by parameter setting.
#7
27001
#6 #5 #4 #3 #2 #1
SPK
#0
SPK When SPART OUT data is altered in the thread process:
1: The amount of the increase or decrease is reflected in the number of
cuts in threading.
0: The amount of the increase or decrease is not reflected in the number
of cuts in threading. (The original number of cuts remains
unchanged.)
9.1
SPECIFICATIONS
9.2
DETAILS
9.3