2.MEASUREMENT CYCLE B-63874EN-1/02
- 108 -
α: Value of “APPROACH DISTANCE FOR 1ST
MEASUREMENT" in the measurement condition of the group
number specified in "MEASUREMENT COND."
β: Value of "ESCAPING DISTANCE FOR 1ST
MEASUREMENT" in the measurement condition of the group
number specified in "MEASUREMENT COND."
ε: Value of "ESCAPING DISTANCE FOR 2ND
MEASUREMENT" in the measurement condition of the group
number specified in "MEASUREMENT COND."
γ: Value of "OVERLAP DISTANCE FOR MEASUREMENT" in
the measurement condition of the group number specified in
"MEASUREMENT COND."
r: Value obtained by dividing ("STYLUS BALL 1ST AXIS
DIAMETER" in the calibration data of the group number
specified in "MEASUREMENT COND.") by 2
Motion depending on the number of measurement points
When "MEASUREMENT POINT" is set to 1, a measurement is made
in the +X-axis direction only.
When "MEASUREMENT POINT" is set to 2, a measurement is made
in the +X-axis and -X-axis directions only.
When "MEASUREMENT POINT" is set to 3, a measurement is made
in the +X-axis, -X-axis, and +Y-axis directions only.
Rapid traverse rate when bit 2 (RPDF) of parameter No. 12380 is set
to 1.
When "MEASUREMENT POINT" is set to 1, a measurement is made
in the +Y-axis direction only.
When "MEASUREMENT POINT" is set to 2, a measurement is made
in the +Y-axis and –Y-axis directions only.
When "MEASUREMENT POINT" is set to 3, a measurement is made
in the +Y-axis, -Y-axis, and +X-axis directions only.
G code format
When you press the INSERT key after entering necessary data, a G
code program in the following format is stored in the machining
program memory:
G2004 Q D
H V L R F P S Y ;
Measurement result
When G2004 is executed, center offsets of the stylus ball in the X-
axis and Y-axis directions are found from entered center X and Y
coordinates and measured values, and are output to the calibration
data and macro variables for the result of measurement.