7.1. Set-Up Guidance Function for Multi-path Lathe
The set-up guidance functions can be used for the multi-path lathe system.
NOTE
In the case of using the Manual Measurement Function, it is necessary
to set the following parameter to ‘1’
Parameter SPT(No.27400#0)
=0 Display path is selection by the software key
=1 Display path selection by the HEAD switch signal
(Reason)
On the manual measurement screen, the manual operations, like the
manual handle feed, are usually executed. And the path of executing
the manual operation is selected by the HEAD switch signal.
So if the display path is different from the path which is selected by
the HEAD switch signal, it is not possible to find executing the
measurement correctly because of the difference between the
display axis data and the actual measurement positions.
Ed.
Date
Design
Description
Name
Draw.
FANUC MANUAL GUIDE i
(Series16i/18i/21i-MB/TB)
OPERATOR’S MANUAL
B-63874EN-1/02-2
Page
FANUC LTD.
3/14