2.MEASUREMENT CYCLE B-63874EN-1/02
- 182 -
2.5.7 Inside Width Measurement
When the probe is oriented in the Z-axis direction, the width of a
groove is measured.
Select "INSIDE WIDTH MEASUREMENT (PROBE Z-AXIS)" on
the post-machining inspection menu selection screen of the
measurement cycle.
Measurement motion screen
The displayed items are the same as for "INSIDE WIDTH WORK
SETUP (PROBE Z-AXIS)".
Input screen for automatic tool offset value setting (turning side)
The displayed items are the same as for "OUTSIDE WIDTH
MEASUREMENT (PROBE Z-AXIS)".
Measurement motion
The description of measurement motion is the same as for "INSIDE
WIDTH WORK SETUP (PROBE Z-AXIS)".
G code format
When you press the INSERT key after entering necessary data, a G
code program in the following format is stored in the machining
program memory:
G2046 P Q
D H V L R F W I S Y U J
K E ;
Measurement result
When G2046 is executed, the groove width is found from the
measured value, and the compensation value obtained from the
difference is output to macro variables for the result of measurement
and as a specified tool offset value.