4.MEASUREMENT RESULT DISPLAY SCREENS B-63874EN-1/02
- 272 -
4.1.2 Data Displayed on the RESULT Screen
Measurement date and time
The displayed measurement date and time data includes year, month,
day, hour, minute, and second.
(Example) 2001 11/06 12:34:56
Measurement type
Whether the machine is in the automatic or manual mode is indicated
along with the type of the measurement performed.
(Example) AUTO-OUTSIDE DIAMETER (MEASUREMENT
PROBE Z-AXIS)
TARGET
The characters representing up to two axis addresses and the related
numeric data are displayed.
• Results obtained when the machine is in the manual mode:
The target used on the post-machining inspection menu is
displayed.
(Example) Circle outside diameter 'D 99999.999'
• Results obtained in automatic measurement:
The target used on the post-machining inspection menu is
displayed.
(Example) Circle outside diameter 'D 99999.999'
The reference coordinates used on the centering function menu
are displayed.
(Example) Circle center 'X -12345.678', 'Y-12345.678'
RESULT
The characters representing up to three axis addresses and the related
numeric data are displayed.
(Example) Touch sensor position measurement 'X-12345.678', 'Y-
12345.678', 'Z-12345.678'
JUDGE
Whether the measurement result was OK or NG and whether an offset
value was changed are displayed only in automatic measurement.