Ed.
Date
Design
Description
Name
Draw.
FANUC MANUAL GUIDE i
(Series16i/18i/21i-MB/TB)
OPERATOR’S MANUAL
B-63874EN-1/02-3
Page
FANUC LTD.
47
64
Data Entry Window (Angled Surface Measurement (Probe Z-axis direction))
MEASURE
Input Item Meaning
P MEASUREMEN
T DIREC.
Measurement Direction
Select from [+X][-X][+Y][-Y] soft keys.
Q MEASUREMEN
T COND.
Measurement Conditions Group Number
H 1ST MEASURE
POINT X
X coordinate value of 1st measurement position (From
where the probe is moved toward the work piece).
V 1ST MEASURE
POINT Y
Y coordinate value of 1st measurement position (From
where the probe is moved toward the work piece).
C 2ND MEASURE
POINT X
X coordinate value of 2nd measurement position (From
where the probe is moved toward the work piece).
D 2ND MEASURE
POINT Y
Y coordinate value of 2nd measurement position (From
where the probe is moved toward the work piece).
A ROTATION
ANGLE
Angle of Work-piece from +X axis direction
L HEIGHT OF
MEAS. PT.
Height of a measurement point in the Z-axis direction.
R APROCH
DISTANCE
Move distance from the approach point to the
measurement point in the Z-axis direction.
F MOVING
MEAS. SPEED
Feed rate for measurement