B-63874EN-1/02 2.MEASUREMENT CYCLE
- 119 -
<5> Then, a rapid return movement is made by ε in the +X-axis
direction.
If the coordinates of the "sensor position for measurement in the -X
direction" of the touch sensor position are shifted from the
coordinates of the tool measurement position, specify the shift in
"SPECIFY OF X, Y, or Z SHIFT".
For example, the motion described below is made when a soft key
other than [AUTO] is selected in "SPECIFY OF Z SHIFT".
• If [OFSET+] is selected in "SPECIFY OF Z SHIFT", the
approach point (Z coordinate) represents (Z coordinate of the
"sensor position for measurement in the -X direction" of the
touch sensor position + OFS
H
).
• If [INPUT+] is selected in "SPECIFY OF Z SHIFT", the
approach point (Z coordinate) represents (Z coordinate of the
"sensor position for measurement in the -X direction" of the
touch sensor position + the value entered in
"OFFSET/DIFFERENCE Z").
• If [DIFF+] is selected in "SPECIFY OF Z SHIFT", the approach
point (Z coordinate) represents (Z coordinate of the "sensor
position for measurement in the -X direction" of the touch sensor
position + (OFS
H
+ the value entered in
"OFFSET/DIFFERENCE Z")).
• The descriptions above apply to the input in "SPECIFY OF X
and Y SHIFT" and motion in the X-axis and Y-axis.
- Measurement of an offset value in the +X-axis direction (measurement of an offset
value in the tool radius direction)
Same as for measurement in the -X-axis direction
- Measurement of an offset value in the +Y-axis direction (measurement of an offset
value in the tool radius direction)
Same as for measurement in the -X-axis direction
- Measurement of an offset value in the -Y-axis direction (measurement of an offset
value in the tool radius direction)
Same as for measurement in the -X-axis direction
The symbols used above have the following meanings:
f: Value of “FEED-RATE FOR 1ST MEASUREMENT" in the
measurement condition of the group number specified in
"MEASUREMENT COND."
β: Value of "ESCAPING DISTANCE FOR 1ST
MEASUREMENT" in the measurement condition of the group
number specified in "MEASUREMENT COND."
γ: Value of "OVERLAP DISTANCE FOR MEASUREMENT" in
the measurement condition of the group number specified in
"MEASUREMENT COND."