Ed.
Date
Design
Description
Name
Draw.
FANUC MANUAL GUIDE i
(Series16i/18i/21i-MB/TB)
OPERATOR’S MANUAL
B-63874EN-1/02-3
Page
FANUC LTD.
44
64
English:「SET DESTINATION MACRO VARIABLE IS NOT
EXIST.」
When press [Setting] soft key with leaving input item [macro variable]
blank, the following warning is displayed in a red.
English:「SHORT INPUT DATA.」
By press [Setting] soft key, the angle calculated from the measurement
result, and macro variable to be set are saved to measurement result
list.
<10> By pressing [ROTATE] soft key, it is output a coordinate system
rotation command G68 by the angle set at specified macro variable at
input item “macro variable”, and it automatically rotate the coordinate
system.
Before operating a measurement, or before [Setting] is pressed,
coordinate system rotation is possible to operate by press [Rotate] soft
key.
Caution
Coordinate System Rotation option is necessary to use this
coordinate rotation function.
Caution
The coordinate rotation command is output as follows.
G68 X#[x]Y#[y]R#[r];
Then in “#[r]” is equal to input item “MACRO VARIAVLE”.
So before executing measurement, Center of Rotation data should
be set to the macro variables of “#[x]” and “#[y]”.
Variable number of #
x
is e
ual to settin
value of “
arameter