<3> Next, a movement is made in the -Z-axis direction to the point
specified "HEIGHT OF MEAS. PT." by G31.
<4> Then, the 1st measurement is made.
Approach Motion when No.27224#0=1
In the case of measurement on XY plane,
<1> A rapid movement is made from the current position to the
measurement start point in the X and Y-axis direction.
<2> In the -Z-axis direction, a movement is made in the -Z-axis direction
to the point specified "HEIGHT OF MEAS. PT." by G31.
<3> Then, a 1st measurement is made.
NOTE
In the case of Outside Diameter Measurement and Outside Width
Measurement, the escape height before moving each measurement
point is to be the position before executing the measurement cycle.
7.2.2.4 OK RANGE and FEED BACK RANGE display
On the data entry window of the measurement cycles, when the parameter
No.27224#1 is set to 1, the input item of OK RANGE and FEED BACK
RANGE do not appear. In this case, the measurement results are feed
backed every time.
L
<1>
<2>
<3>